Terms used across the product and this site, defined the way the standards define them, with a note on where each one shows up in Metroliq.

A to Z

Definitions

TermDefinitionIn Metroliq
As-found / as-leftThe reading before and after any adjustment during calibration.Both stored per point; the interval review uses as-found.
CAPACorrective and preventive action: the record that fixes a cause, not a symptom.Quality module; AI-drafted, human-owned, effectiveness check required to close.
CMCCalibration and measurement capability: the smallest uncertainty a lab can claim on its accredited scope.Uncertainty studies publish as CMC lines; authoritative at perform.
Conditional (verdict)Specification met, but the result is not accepted under the decision rule because the uncertainty interval crosses the limit.Third verdict state; wording prints the probability of non-conformance.
Coverage factor k / probabilityMultiplier turning combined standard uncertainty into expanded uncertainty; k = 2 ≈ 95.45 %.Taken from the t-distribution via effective degrees of freedom; printed on the certificate.
DCCDigital Calibration Certificate, the PTB-led XML schema with D-SI units.Exported for every certificate; imported from other labs.
Decision ruleThe rule that turns a measured value, its uncertainty and a tolerance into a verdict.Simple, guard-banded accept, guard-banded reject, PFA target; printed with the verdict.
Effective degrees of freedomWelch–Satterthwaite combination of the degrees of freedom of the contributors.Computed per budget; picks k.
En score / z scoreProficiency-testing performance statistics comparing a lab's result with the reference.PT/ILC evaluation in the quality module.
FEFOFirst expired, first out: issue the lot with the nearest valid expiry.Inventory issue rule; expired lots refused.
Guard bandA margin inside the tolerance that offsets measurement uncertainty; ILAC-G8 uses w = U.Acceptance limit = tolerance − U; shown per point.
GUMGuide to the expression of uncertainty in measurement (JCGM 100).The budget arithmetic: divisors, quadrature, Welch–Satterthwaite.
Hash chainEach audit entry hashes the previous entry's hash with its own content, so history cannot be edited silently.SHA-256 over canonical JSON; verify endpoint.
Idempotency keyA client-supplied token that makes a repeated write safe.Header on POST/PUT/PATCH; replays return the stored response.
ILACInternational Laboratory Accreditation Cooperation; publishes P14 (uncertainty), G8 (decision rules), G24 (intervals).Applied throughout the calibration module.
Intermediate checkA check between calibrations that a reference standard still performs.Due list per standard.
MSA / Gage R&RMeasurement system analysis: how much variation comes from the gauge and the operators.AIAG Gage R&R studies.
Monte Carlo (JCGM 101)Propagating uncertainty by sampling the input distributions.Seeded, reproducible, 10 k – 2 M trials; cross-checks the GUM budget.
NCRNonconformance report: something did not meet its requirement.Raised at the bench with the failing point; escalates to CAPA.
PFA / PFRProbability of false accept / false reject for a given reading, uncertainty and rule (JCGM 106).Computed per point; printed.
Provenance (AI)The record of which model produced a draft, from what prompt, and who approved it.Ledger entry per draft; certificate states AI-assisted specs.
Reference standardThe calibrated artefact or instrument the unit under test is compared with.Typed per-point accuracy, own certificate and due date; overdue refused.
Revision / amendmentA corrected certificate is a new revision with a reason; the old one is kept.§7.8.8; verify page shows both.
Sensitivity coefficientHow much the output changes per unit change of an input; the partial derivative of the measurement equation.Derived symbolically from the equation and cross-checked numerically.
Specification provenanceWhere a tolerance came from: document, revision, clause, origin.Stored with the spec; printed on the certificate.
TraceabilityAn unbroken chain of calibrations to the SI, each with stated uncertainty.Standards chain and statement on the certificate.
TUR / TARTest uncertainty ratio: tolerance divided by expanded uncertainty (TAR uses the standard's accuracy).Computed from the standard's typed accuracy; declared when below 4:1.
Type A / Type BUncertainty evaluated statistically from repeated readings (A) or by other means such as certificates and specifications (B).Contributor types in the budget.
Validation (IQ/OQ/PQ)Installation, operational and performance qualification of a computerised system.Validation evidence; the OQ runs itself.